Monark 831 E Guide de dépannage

Naviguer en ligne ou télécharger Guide de dépannage pour Conditionnement physique, gymnastique et musculation Monark 831 E. Monark 831 E Troubleshooting guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 2 - Important

- 0 Terminal/PC -1-3 see manual - (0) _1234675Monark 831 E10Connect the terminal to the main unit on the front 1. of the bike (use the 0-modem cable

Page 3 - Contents

Monark 831 E 11PrinterThe 831 E Ergometer interfaces to several optional devices. A parallel interfaced printer may be attached to provide written rep

Page 4 - Monark Exercise AB

Monark 831 E12CalibrationThe 831 E is a mechanically weighted and braked ergometer, making performance validation a simple procedure. Calib

Page 5 - Product Information

200:00 0.0 kcal ♥ 123 000 rpm 00N 0 watt (exemple) 0= Menu 3= Start1Monark 831 E 13Validation o

Page 6 - Operating Instruction

Monark 831 E14Check at the bottom of the flywheel that the 1. brake belt is loose, see Fig: Brake belt is loose. If not, move the pendulum to 4

Page 7 - Initial operation

Monark 831 E 15Fig: 0-positionFig: Check loose brake belt. Fig: 2 kp Fig: 4 kpFig: 6 kp Fig: 0 kp

Page 8 - Connection to controller

Monark 831 E16CalibrationThe 831 E is a mechanically weighted and braked ergometer, making performance validation a simple procedure. The wo

Page 9 - Connection to PC

Monark 831 E 17Electronic calibrationCalibration is necessary to match the mechanics of the ergometer to the electronics of the computer.

Page 10 - Monark 831 E

123456Monark 831 E18Calibration of pendulum weightAlthough all Ergometers are calibrated at the factory the user may wish to verify this by pe

Page 11 - Analogue control

Monark 831 E 19Testing with Ergomedic 831 EThe versatility of the 831 E Ergometer enables it to be utilized in a variety of testing environments. The

Page 12 - Calibration

ImportantRead the manual carefully before using the cycle and save it for future use.

Page 13 - Electronic calibration

Monark 831 E20Subject supervisionThe ergometer performs automated tests virtually by itself, requiring minimal intervention by the operator. This allo

Page 14 - Electronic calibration - PC

Monark 831 E 21Fitness Rating Index - Males Maximum Oxygen Consumption ml/kg/minFitness Rating Index - FemalesMaximum Oxygen Consumption ml/kg/minRati

Page 15

Monark 831 E22Operation interferencesIt is normally considered that about 70 % of all shutdowns on small computers are caused by mains interferences,

Page 16

Monark 831 E 23Error messagesMessage ReasonTest Aborted An automatic protocol operation has been stopped too early. No results are available.Reference

Page 17

WarrantyEU countries - Private useIf you are a consumer living in the EU you will have a minimum level of protection against defects in accorda

Page 18

BatteriesIf the meter is battery-operated, the batteries are in a separate package at delivery. If the storing time has been long the battery

Page 19 - Testing with Ergomedic 831 E

Chain 1/2“ x 1/8“It is strongly recommended to keep the chain clean. Dirt build-up on the chain will cause excess wear. A chain lubricant and solve

Page 20 - Heart rate (Telemetry system)

Freewheel sprocketWhen replacing the freewheel sprocket remove frame covers if necessary. Dismantle the chain as described in part ”Chain 1/2” x 1/8”

Page 21 - Reviewing results

1 2 3 575655514243444145394050 34 35 6037 4 3824 25 26 28 29 30 31 23 47 48 14 21 22 15 19 17 18 16 15 25 32 33 27 7 8 9 53545 12 49 11 46 6 26 13 10

Page 22 - Troubleshooting guide

Monark 831 E 29Pos. Qty. Art. No. Description Pos. Qty. Art. No: Description1 1 9339-38 Frame for equipment 31 1 9339-32 Spacer2 4 9300-21 Screw MVBF

Page 23 - References

Monark Exercise AB ����������������������������������������������������������������4Product Information ��������������������������������������������

Page 24 - Warranty

232527262930121311514151691087171819202122612432824Monark 831 E30Pos. Qty. Art. No. Description Pos. Qty. Art. No: Description1 1 9300-50 Chain guard

Page 25

231Monark 831 E 31Pos. Qty. Art. No: Description Pos. Qty. Art. No: Description1 1 9391-80 Table stand, complete, height-adjustable3 2 9000-29 Trans

Page 26 - Chain 1/2“ x 1/8“

KROONS VÄG 1, SE-780 50 VANSBRO, SWEDEN | WWW.MONARKEXERCISE.SE | TEL: +46(0)281 59 49 40 | FAX: +46(0)281 719 81Version 1010Art. No: 7950-298

Page 27 - Freewheel sprocket

Monark 831 E4Monark Exercise ABMonark has 100 years’ experience of bicycle production. The Monark tradition has yielded know-how, experie

Page 28 - Spare parts

1Monark 831 E 5Product InformationCongratulations on your new Ergometer.The Monark Ergomedic 831 E is a stable armergometer that qualify for the fi

Page 29

Monark 831 E6Operation of the ergometerThe Ergomedic 831 E is built on a stabile frame, a well-balanced flywheel, a break belt and a pendulum weight wh

Page 30

1684216842Metro/PulsRPM311Monark 831 E 7Fig: Rpm displayHeight adjustment of table standThe height of the table stand can be adjusted to get the ergom

Page 31

- 0 Terminal/PC -1-3 see manual - (0) _12 34675Fig: Connection1) Printer connection2) Power switch3) Power connection4) LED5) Chassis ground6) Termin

Page 32 - Art. No: 7950-298

Monark 831 E 9Connection to PCTo connect a PC to the ergometer, use a 0-modem cable (RS232) with a 9-pin D-sub female at each end. If no RS23

Commentaires sur ces manuels